Drug Discovery

Lead Optimization

Bruker’s product suite delivers high quality, data-rich information to make the rational decisions in an efficient lead optimization process.

Overview

Once leads have been identified successfully, lead optimization starts to bring potent and safe drug candidates into the preclinical phase. Relevant aspects like affinity, selectivity, mode of action, synthesizability and ADMET-properties are typically improved in a multiple design-make-test-analyze (DMTA)-cycles. Bruker’s solutions provide fast, high-quality responses to ensure a high iterative pace in the DMTA-cycles required for the shortest possible time-to-market.

Picture provided by Maximilian Benz

A crucial element for any lead optimization project is the development of easily synthesizable compounds and analogs thereof. Novel synthetic technologies like microbatch synthesis allow to easily cover a broad chemical space by combinatorial synthesis but create the demand for the fast analysis of millions of compounds at volumes of a few nl only. Bruker’srapifleX MPPperfectly addresses this need and screens at highest pace to ensure rapid reaction control and surveillance of the chemical reactivity landscape. More detailed chemical information regarding structure, isomerization and reaction control based on larger volumes can easily be assessed byNMR,X-ray diffraction(XRD), and with thetimsTOF Pro MS.Single-crystal X-ray diffraction(SC-XRD) (Link5) delivers a detailed picture of the 3D connectivity and arrangement of the atoms in the organic molecule.

A key element in lead optimization is to establish a structure-activity relationship in order to develop more potent ligands.X-ray methods, such assmall angle X-ray scattering(SAXS) andsingle-crystal X-ray diffraction提供蛋白质的结构信息n-ligand complex, thus providing insights into spatial orientation of the ligand which is essential to rationally design more selective or potent ligands. Perfectly complementary for smaller proteins,NMRgives structural information about binding and dynamics in physiological conditions.

Modern lead optimization requires details on temporal stability of a protein-analyte complex as early as possible. This information can be derived from the kinetic constants, like dissociation rate constants.Surface Plasmon Resonance(SPR) is highly suited at this stage as the real-time, label-free analysis of the kinetics offers direct insights beyond affinities or IC50. Moreover, the high flexibility of SPR Bruker systems allows to simultaneously investigate the binding of lead structures to up to 31 target proteins offering insights into specificity and selectivity.
Additionally, SPR allows to investigate the enthalpic and entropic contribution, key characteristics in lead optimization processes. The influence of co-factors and medium conditions such as tissue-specific pH on a protein-ligand interaction can further be analyzed by SPR.

Bruker’s mass spectrometry portfolio offers an additional layer of insight relevant during lead optimization. ThetimsTOF Promakes use of the Parallel Accumulation Serial Fragmentation (PASEF) acquisition method, thus offering highly reliable, sensitive and fast insights into proteomics for in vitro mode of action studies. Furthermore, native MS-conditions allow to investigate protein-ligand complexes in orthogonal fashion, additionally providing information on stoichiometry besides affinities, selectivity and binding modes.

Eventually, lead optimization is also driven by improvements ofADMET-properties. Bruker’s SC-XRD, NMR, SPR and MS solutions are perfectly suited for the investigation all the way from binding assessment with plasma proteins (e.g. for increase of half-life) and metabolite analysis to distribution and toxicology studies. Most recently, ourMALDI-imagininghas turned out to be especially powerful studying the toxicology profile of compounds. Bruker’smagnetic resonance MS systemsdeliver a market-leading resolution of > 290’000 mass resolutions at m/z 400, thus enabling a comprehensive mapping of a compound.

有趣的铅化合物properti进行了优化es are likely to be tested in in vivo studies using both transgenic and disease models at the later stages of lead optimization. Conventionally, small rodents are used and often require ‘snap shot’ investigations where single time point experiments are carried out on excised tissue. However, Bruker’spreclinical imaging systemssuch as theBioSpec MRIandSkyscan micro CTcan provide precise events during the disease that may be pertinent to the particular efficacy of the molecule. Bruker’s preclinical platform provides the ability to measure quantitatively and precisely anatomical, functional, metabolic and cellular mechanisms. The high data quality is ensured by longitudinal experiments where live results can influence the decision making much earlier compared to ex vivo tissue assessments. In addition, temporal in vivo biomarkers assessment within animal not only reduces total numbers of animals used but provides information on mechanisms in the intact fully functioning organ/tissue.

Related Products

Related Products

D8-VENTURE-900x500

D8 VENTURE

D8 VENTURE - the Standard for Quality and Versatility in Single Crystal XRD
D8 DISCOVER

D8 DISCOVER Family

The D8 DISCOVER Family is the ultimate multi-purpose X-ray diffractometer platform offering leading technology components. It is designed for the structural characterization of the full range of materials from powders, polycrystalline materials to epitaxial multi-layered thin films.
Ascend 400

NMR Instruments

NMR is an information rich, non-destructive analytical technique. It provides detailed information about molecular structure, dynamic processes and allows the direct observation of chemical reactions.
rapifleX MALDI PharmaPulse

rapifleX®MALDI PharmaPulse®

The rapifleX® MALDI PharmaPulse® (MPP) enhances label-free HTS combining the unambiguousness of mass spectrometry with the required speed to comb through large compound libraries of millions of substances.
timsTOF Pro

timsTOF Pro

The new standard for 4D-Proteomics™ delivers revolutionary improvements in scan speed, with enhanced specificity and high sensitivity, using TIMS powered by PASEF® technology.
scimaX

scimaX

scimaX is powered by 2xR MRMS technology, bringing the "high hanging fruit" within easy reach.
NANOSTAR

NANOSTAR

The NANOSTAR with its incomparable modularity is the ideal tool for characterization of nanostructures ranging from 1 nm to roughly 125 nm, and nanostructured surfaces by SAXS, GISAXS and Nanography.
SPR-32 Pro

Sierra SPR-32 Pro

From initial screening to detailed kinetic characterization and thermodynamics measurements, Sierra SPR-32 Pro enables high-throughput SPR analysis of molecular interactions.
Fourier 80

Fourier 80

Building on decades of experience creating top-quality NMR instruments, Bruker has reimagined high-performance NMR spectroscopy in a compact, cost-efficient form
Biospec_3T_teaser

BioSpec 3T

The BioSpec 3T with its small footprint and minimal site requirements perfectly fits into existing lab structures, expanding biomedical research capabilities with easy-to-use MRI. Innovative Maxwell technology eliminates the need for liquid Helium and makes use inherently safe.
Bruker_SKYSCAN-1272_CMOS

SKYSCAN 1272 CMOS EDITION

High resolution benchtop microCT with vibration isolation, CCD detector and micro-positioning sample stage.
Micro-CT for Life Science

Micro-CT for Life Science

Micro computed tomography is X-ray imaging in 3D, by the same method used in hospital CT scans, but on a small scale with massively increased resolution. It really represents 3D microscopy, where very fine scale internal structure of objects is imaged non-destructively.

Webinars

Support

Labscape

Service & Life Cycle Support for Magnetic Resonance and Preclinical Imaging

Bruker’s commitment to provide customers with unparalleled help throughout the buying cycle, from initial inquiry to evaluation, installation, and the lifetime of the instrument is now characterized by the LabScape service concept.

LabScape Maintenance Agreements, On-Site On-Demand and Enhance Your Lab are designed to offer a new approach to maintenance and service for the modern laboratory