QTOF

Quadrupole Time-of-Flight (QTOF) Mass Spectrometry

Cutting-edge QTOF performance helps analyze thousands of compounds
QTOF

QTOF Mass Spectrometry

Since its first commercial launch 25 years ago, quadrupole time-of-flight (QTOF) mass spectrometry (MS) has revolutionized numerous fields, ranging from biological and pharmaceutical research to clinical toxicology. The unique hybridization of quadrupole and TOF technology resulted in high-resolution, high mass accuracy analysis of all ions simultaneously, which is today used to identify and quantify complex mixtures or unknown compounds.

The MS/MS capabilities of QTOF MS systems enable coupling to both LC and GC systems and Bruker’s expertise provides a variety of innovative instruments. Our powerful, high performance products are specifically designed to meet the rapidly growing needs of customers in the academic, pharmaceutical, industrial, clinical, and applied markets.

QTOF

QTOF MS Instruments

impact II

The impact II sets a technology standard for analytical performance in residue and contamination screening, forensics, industrial and synthetic chemistry, biomarker research, and more, with unparalled ultra-high resolution Qq-time-of-flight mass spectrometry.

maXis II

The latest in cutting-edge LC-QTOF MS technology provides enhanced resolution and mass precision for intact protein analysis, characterization of biopharmaceuticals, and native mass spectrometry analysis.

timsTOF

Engineered by as an open platform to accelerate the adoption of ion mobility-mass spectrometry analysis across research applications.

timsTOF Pro 2

The timsTOF Pro 2, powered by the latest parallel accumulation serial fragmentation (PASEF®) technology, paves the way to 4D-Proteomics and 4D-Lipidomics with unbiased cell and plasma proteomics and liquid biopsy multiomic biomarker discovery, integrating genomics with proteomics and epiproteomics.

timsTOF fleX

Fully functional high speed, high sensitivity ESI instrument for all X-Omics analyses, now available with the innovative and powerful MALDI-2 technology option.

紧凑的

The powerful technology required for research applications is now available in a compact, robust and economic benchtop Qq-TOF system for high dynamic range analyses.

TargetScreener HR

A complete QTOF solution based upon accurate mass measurements, covering the analysis of drugs, pesticides, PCPs and more, found in a variety of complex matrices such as food, saliva, urine, serum and environmental samples.

QTOF Technology

Bruker offers a broad range of different ionization sources to allow coupling of various separation techniques with the benefits of high-resolution mass spectrometry. In mass spectrometry, the performance of the MS system in terms of mass resolution, mass accuracy and principally sensitivity, is highly dependent on the method of ion generation.

Once ions are generated they are guided by a capillary inlet system and a dual ion funnel into the quadrupolar system for isolation (MS) and controlled fragmentation (MS/MS).

Orthogonal acceleration follows the quadrupolar units and divides the permanent stream of ions in discrete packages being shot into the flight tube. At its top end they get reflected for improved resolving power and focusing onto the detector multi-channel plate.

QTOF Applications

结构蛋白质组学
研究人员在生物制药科学基于“增大化现实”技术e increasingly tasked with gaining a deeper knowledge and understanding of the effects interactions and stressors, such as pH or temperature, have on the conformational structure of biotherapeutic proteins. This is a very challenging task and researchers often use a variety of analytical tools to study the higher order structure of the biotherapeutics, monitor protein/protein-drug interactions and perform epitope mapping.

In recent years Hydrogen Deuterium Exchange Mass Spectrometry (HDX-MS) has emerged as a valuable technique within the arsenal of analytical tools available for providing such insights into protein structure conformation. However, until recently HDX-MS was confined mostly to academic research laboratories, due to a lack of automation and limited data interpretation tools, as well as the need to have reliable monoisotopic mass assignments.

Metabolomics
Several crucial steps are important for confidently identifying compounds relevant for dynamic metabolic processes; including sample preparation, data acquisition and data evaluation.

Meaningful insights in a biological context can only be obtained if all of the steps in a workflow are controlled.

The acquisition of high quality LC-MS/MS data follows sample preparation in non-targeted metabolomics workflows, with the T-ReX®LC-QTOF solution, no LC-MS/MS parameter optimization is required. To analyze large sample cohorts which require high retention time stability the Elute UHPLC in combination with the dedicated T-ReX®Elute Metabolomics-kit: RP is provided. The Reversed-Phase LC column kit enables matching of retention times to values in the Bruker HMDB Metabolite Library. The impact II for MS/MS data acquisition uses optimized parameters and its robust performance is the basis for high quality data acquisition, enabling extensive profiling studies of complex samples.

Contaminants and Residues Screening
Analysing complex food or water samples for pesticides, mycotoxins etc. or equally challenging human or animal urine analysis samples for poisons or drugs is a demanding application. Bruker offers a powerful solution based upon accurate mass analysis and highly curated databases (over 3000 compounds) to ensure reporting false positives (or false negatives) is minimized.

QTOF Related Information

Structural proteomics:

Contaminants and residues screening:

For Research Use Only. Not for use in clinical diagnostic procedures.